SIF Design Tab Layout
This tab is used to do the SIF Design. The aim is to design the Subsystems in terms of their Equipment Actuators and Test Intervals , such that the Achieved PFD is equal or higher than the Target PFD , while ensuring that the Success ...
Written by
Elsa Tolsma
,
Denis Tkalec
,
Tomislav Renic
Updated on : 09 Aug 2024
Designing SIF Subsystems (Building the Hardware Configuration)
The Subsystems that were added on the General tab can be further defined/designed on the Design Tab in terms of the Equipment Actors. To add or remove Equipment Actors, just click + or - . Click + or - to add or remove Equipment Actor...
+ 1
Written by
Elsa Tolsma
,
Iva Vukovic
,
Denis Tkalec
and 1 others
Updated on : 09 Aug 2024
Defining SIF Success Criteria
Success Criteria for the SIF Analysis is defined in terms of the Equipment- Actors . The table below summarizes the Success Criteria nomenclature. Typical Success Criteria nomenclature used: The of Success Criteria must be defined o...
+ 1
Written by
Elsa Tolsma
,
Iva Vukovic
,
Denis Tkalec
and 1 others
Updated on : 22 Oct 2024
Tuning and Setting SIF Test Intervals
Each Equipment- Actor can have multiple proof Tests . These are defined on the Equipment level. The aim is to set an interval for each of these Tests, which ensures an Achieved PFD < Target PFD (see Calculating SIF Achieved PFD...
+ 1
Written by
Elsa Tolsma
,
Iva Vukovic
,
Denis Tkalec
and 1 others
Updated on : 09 Aug 2024
Calculating SIF Achieved PFD and Verifying Integrity
You need to verify that the Achieved PFD is less than the Target PFD . (The Target PFD is normally calculated during the LOPA Assessment , but if not connected to a LOPA it could also be a static value that you enter on the SIF Analysi...
+ 1
Written by
Elsa Tolsma
,
Iva Vukovic
,
Denis Tkalec
and 1 others
Updated on : 09 Aug 2024
Verifying SIF Dangerous Fault Tolerance requirements
The DFT ( Dangerous Fault Tolerance ) requirements for the SIF Analysis are checked on the Subsystem level. The SIF design (Equipment selected in the Subsystem and Equipment Success Criteria ) is checked against the DFT requirements that are se...
+ 1
Written by
Elsa Tolsma
,
Iva Vukovic
,
Denis Tkalec
and 1 others
Updated on : 09 Aug 2024
Verifying SIF Performance
The Performance for the SIF Analysis is verified per Subsystem . Performance is verified per Subsystem. The Performance check considers two criteria: Sensor Accuracy (on the Sensor ) Tight Shut-Off ( TSO ) for valves (on the...
+ 1
Written by
Elsa Tolsma
,
Iva Vukovic
,
Denis Tkalec
and 1 others
Updated on : 16 Sep 2024
Verifying SIF Response Time
For the SIF Analysis the Overall Functional Response Time is calculated as the longest response times of the Sensor Subsystems plus the longest of the Logic Solver Subsystems and the longest response time of the Final Element Subsystems ...
+ 1
Written by
Elsa Tolsma
,
Iva Vukovic
,
Denis Tkalec
and 1 others
Updated on : 09 Aug 2024
Approving the SIF Design
When all is verified ( Achieved PFD checked, Performance checked, and Response Time checked) then you can Approve your design in the Approval area. Approval Prerequisites The following Approval rules apply: Unrated SIFs Approval is a...
+ 1
Written by
Elsa Tolsma
,
Iva Vukovic
,
Denis Tkalec
and 1 others
Updated on : 09 Aug 2024
SIF Assessment Status
Each SIS Analysis has an AS (Assessment Status) associated with it. This is shown on the SIF Analysis Main Screen , as well as on the General Tab . The Assessment Status indicator turns green (OK) when: A Target SIL ( Target PFD ) is availa...
+ 1
Written by
Elsa Tolsma
,
Iva Vukovic
,
Denis Tkalec
and 1 others
Updated on : 09 Aug 2024
SIF Design Status
Each SIF Analysis has a DS (Design Status) associated with it. This is shown on the Analysis Main Screen , as well as on the Details Page General Tab and Design Tab . DS Indicator for Unrated (-) SIFs Not Applicable - When the Assessme...
+ 1
Written by
Elsa Tolsma
,
Iva Vukovic
,
Denis Tkalec
and 1 others
Updated on : 09 Aug 2024
Change password!
Changing your password will log you out immediately. Use the new password to log back in.
Current password
Current password is required
New password
New password must be at least 8 characters long. It should contain at least one upper and lower case letter, number, and a special character.
Confirm password
Confirm password must be at least 8 characters long. It should contain at least one upper and lower case letter, number, and a special character.
Confirm password should be same as new password
Update
Change profile
Success!
First Name
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last Name
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
New email
Enter a valid email
Re-enter your password
Enter a valid password
Your profile has been successfully updated.
Update
Logout
ENTER
ESC
Eddy AI, facilitating knowledge discovery through conversational intelligence
Search Limit Exceeded. Please upgrade the plan.
Answer copied!
No results found
Provide more context or information so that I can better understand and assist you