You are ready to start the Extreme Value Analysis when:
- EVA is activated;
- The CMLs have measurements;
- The Nominal WT and Renewal thickness are filled in for all the CMLs with measurements; and
- The Equipment has a start date.
(See Preparing for an EVA.)
Open the EVA Page
To open the EVA page:
- Click on the EVA button.
- You are directed to the EVA page.
Define Stratification(s)
Important
At least one Stratum is required to do an EVA calculation.
Note: It is recommended to use 20-30 tubes per Stratum. More than this can lead to non-conservative estimates.
To define the Stratifications:
- First, create a Default Stratum for all CMLs:
- Select the CMLs in the CML grid or hold <Ctrl> and select the CMLs directly from the HX Overview.
- Click the Stratification button on the CML toolbar (small EVA icon) & fill in the New stratum name.
- Click Confirm.
- Look at the Histogram below the CMLs (and change the Step Value if desired). This gives an indication of the measurement spread.
Important
For each Stratum one should aim for a homogenous spread, i.e., only CMLs or tubes subject to the same Degradation Mechanisms and thus corrosion behavior.
- If required, create more Stratums:
- Select desired CMLs.
- Click the Stratification button to define / redefine a Strat.
- Review the Histograms (per Strat) again.
Run the EVA Calculations
To run the EVA calculations:
- Press the Calculate button at the top of the EVA page.
- IMS will fit a Gumbel distribution for every Strat and do an extrapolation in space.
- When the calculation is done, the EVA Calculation Charts grid will be populated - one row for each Strat, showing CR, etc.
Review the Results
Now it is time to review the results.