How: RSL Care Strategies provide decision logic on RSLs where based on Floc and Eq data, e.g. Specs, tasks can be applied, or not.

Floc and Eq specs

On Flocs and Equipment Specs can be available, some Specs originate from SAP, for instance via a data-interface, some Specs can be imported in IMS.
Below picture show an example of the spec 'ECS OVERHAUL REPLACEMENT' on the valves 13LCV010 and 13LCV011, with the data: 13LCV010: YES - 13LCV011; NO

LCV11 - 0 YN.png

Specs can be entered manually - one-by-one - or via an Export-for-Import::

Specs.png

Note that as there can be various Specs relevant for the different Location types and Equipment groups, in the Export-for-Import wizard there is a sub-step to select the relevant set of Specs. As such it might work better - to limit the vairation in Location types and Equipment groups, for each Export-for-import:

Specs E4I.png

With insight in the available Specs, we recommend to set up a story-line from the Location type/ Equipment group, to the relevant FM's and to the applicable maintenance tasks.
The objective is to get a line of sight what the effect of the different Specs might be on the FM scenario and on the various applicable tasks.

Effect of Spec on FM and Tasks

Herewith an example for a Control valve with Failure Mode: Actuator Failure.
If we consider intense time base degradation of the actuator, we indicate that we like to do Cleaning and Storke test every 4 years.
If we consider minor degradation of the actuator, we indicate that we like to do Cleaning and Storke test every 10 years.

GCV - Spec 1.png

Using the ECS OVERHAUl REPLACEMENT Spec, we can steer the 4 yr tasks on a 'YES' and the 10 yr tasks on a 'NO'.

Set up Selective RSL

With insight in the tasks involved the RSL can be created, with the tasks involved:
`RSL tasks Spec1.png

In the RSl we can create the first Strategy: 'Time Based Degradation High':

RSL - Strat.png

With the strategy created in the RSL we can [Edit ] it - and select tasks:

RSL - Strat 2.png

For the selected tasks the Strategy requirements can be set up, for the relevant Spec: ECS OVERHAUl REPLACEMENT = YES

RSL - Strat 3.png

After saving, the 'Minor degradation case of the actuator' can be added as second Strategy to the Selective RSL by [+] and selecting the tasks involved:

RSL - Strat 5.png

Note:

In the logic used- and selection of Spec variables, you can select, what should be in, or what NOT should be in:

Strategy specs.png

Finally the RSL should be Approved for actual use, where the data cannot be editted anymore:

RSL - Strat 7.png

Assign Flocs to the Strategy

To assign Flocs (or Eq) to the Strategy a 'Bulk Assign to Strategy' wizard is available:

Assign to strategy 1.png

In this example we use the Control valve Flocs 13LCV010/-11/-12 as used above, where 13LCV012 has no Spec data - to illustrate the effect of that.
The new Bulk Assign also includes assignment to a System, Function and Functional Failures.

Assign to strategy 2.png

In the Next step the decison logic becomes active.
On 13LCV010 we see that the ECS OVERHAUl REPLACEMENT Spec = YES connects to the 'TB degradation high'
On 13LCV011 we see that the ECS OVERHAUl REPLACEMENT Spec = NO connects to the 'TB degradation low'
On 13LCV012 we see there is no Spec - so the RSL is not selected.

Assign to strategy 4.png

A warning pops up in case multiple Functional failures are availabe - to connect from the RSL Strategy to a (1) Functional Failure (FF).

Note

In case of multiple FM's - all will be connected to one Functional
Failure. In the System FM's can be moved easily from one FF to another FF

Assign to strategy 3.png

After the FF's are selected Labels can be asdded, and the Assignment action can be reviewed.

Assign to strategy 6.png

In the end the RSL and Strategies are Assigned toe the Flocs 13LCV010/-11:

Assign to strategy  Fin.png

From the Selective RSL these 6 tasks are created:

tasks.png

Note:

During the Buk Assignment Strategy process, the individual 'to be asigned' tasks can be viewed, when the strategy is selected using the blue arrow:

ECS tasks.png


Was this helpful? Click to add feedback comments

Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.
ESC

Eddy AI, facilitating knowledge discovery through conversational intelligence