--- title: "Hydrocor Case Study" slug: "hydrocor-co2-use-case" updated: 2026-10-27T23:12:11Z published: 2026-10-27T23:12:11Z canonical: "ims-handbook.cenosco.com/hydrocor-co2-use-case" --- > ## Documentation Index > Fetch the complete documentation index at: https://ims-handbook.cenosco.com/llms.txt > Use this file to discover all available pages before exploring further. # Hydrocor Case Study > [!NOTE] > Take Note > > This article explains how to creating and running a new CO2 corrosion assessment using the [Full Hydrocor](/v414/docs/learn-about-full-hydrocor) module for a Pipeline in the IMS system: - Open the Pipeline’s “HC10_Case01_02_03_CO2_corrosion” Equipment Details Page. - Open the Internal Corrosion Module. ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/Screenshot_628.jpg?sv=2026-02-06&spr=https&st=2026-10-28T19%3A11%3A52Z&se=2026-10-28T20%3A11%3A52Z&sr=c&sp=r&sig=g5K3%2BLNxmd26a0xGEI6UABDJ7GHuSkru79zeaMjH3FA%3D) - In the Hydrocor section, click the + button to create a new Assessment. ![A screenshot of a computer AI-generated content may be incorrect.](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/hydrocor-image-t0s39hcf.jpg?sv=2026-02-06&spr=https&st=2026-10-28T19%3A11%3A52Z&se=2026-10-28T20%3A11%3A52Z&sr=c&sp=r&sig=g5K3%2BLNxmd26a0xGEI6UABDJ7GHuSkru79zeaMjH3FA%3D) - Enter the Date as “01/Jun/2025”. - Enter the assessment Name as “Case 1 CO2 corrosion”. - Click **Save**. ![A screenshot of a computer AI-generated content may be incorrect.](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/hydrocor-image-434j2y1j.jpg?sv=2026-02-06&spr=https&st=2026-10-28T19%3A11%3A52Z&se=2026-10-28T20%3A11%3A52Z&sr=c&sp=r&sig=g5K3%2BLNxmd26a0xGEI6UABDJ7GHuSkru79zeaMjH3FA%3D) - Click the Hydrocor icon to open the Hydrocor Application. ![A screenshot of a computer AI-generated content may be incorrect.](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/hydrocor-image-x6s6u6b3.jpg?sv=2026-02-06&spr=https&st=2026-10-28T19%3A11%3A52Z&se=2026-10-28T20%3A11%3A52Z&sr=c&sp=r&sig=g5K3%2BLNxmd26a0xGEI6UABDJ7GHuSkru79zeaMjH3FA%3D) - Select the **1 Settings** tab. - Under Degradation Mechanisms select the “CO2” checkbox. ![A screenshot of a computer AI-generated content may be incorrect.](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/hydrocor-image-nin6acj0.jpg?sv=2026-02-06&spr=https&st=2026-10-28T19%3A11%3A52Z&se=2026-10-28T20%3A11%3A52Z&sr=c&sp=r&sig=g5K3%2BLNxmd26a0xGEI6UABDJ7GHuSkru79zeaMjH3FA%3D) If you are running Hydrocor inside IMS PLLS the Service Type, Pipeline Diameter, and Length fields are automatically populated using information from the Pipeline Design Data. - To modify the Service Type, Pipeline Diameter, or Length, return to the Pipeline’s Equipment Details page PL Design Data section. - Click **Edit** and update the parameters as follows:: - Pipeline Length: 1000m - Nominal Diameter: 12”​ - Service Type: Multiphase gas/condensate ![A screenshot of a computer AI-generated content may be incorrect.](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/hydrocor-image-qp6z6fcl.jpg?sv=2026-02-06&spr=https&st=2026-10-28T19%3A11%3A52Z&se=2026-10-28T20%3A11%3A52Z&sr=c&sp=r&sig=g5K3%2BLNxmd26a0xGEI6UABDJ7GHuSkru79zeaMjH3FA%3D) - Click **Save**. - Click the *Internal Corrosion* icon, then select the *Hydrocor* icon to return to the Hydrocor Application. - Select the **2 Main Input** tab and specify the following parameters: - CO2 content gas = 2 mole%​ - Pressure inlet = 120 bara​ - Temperature inlet = 60°C​ - Ambient temperature = 7°C​ - Gas flow rate = 0.5 mln Sm3/d​ - Oil/Condensate flow rate = 200 m3/d​ - Water flowrate = 150 m3/d ![A screenshot of a computer AI-generated content may be incorrect.](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/hydrocor-image-uufyk6kk.jpg?sv=2026-02-06&spr=https&st=2026-10-28T19%3A11%3A52Z&se=2026-10-28T20%3A11%3A52Z&sr=c&sp=r&sig=g5K3%2BLNxmd26a0xGEI6UABDJ7GHuSkru79zeaMjH3FA%3D) - Click the *Run and Save* button to execute the corrosion prediction case. ![A screenshot of a computer AI-generated content may be incorrect.](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/hydrocor-image-4k20n7lo.jpg?sv=2026-02-06&spr=https&st=2026-10-28T19%3A11%3A52Z&se=2026-10-28T20%3A11%3A52Z&sr=c&sp=r&sig=g5K3%2BLNxmd26a0xGEI6UABDJ7GHuSkru79zeaMjH3FA%3D) - Review outputs including corrosion rates, material recommendations, and visualization profiles. ![A screenshot of a computer AI-generated content may be incorrect.](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/hydrocor-image-5c374d2v.jpg?sv=2026-02-06&spr=https&st=2026-10-28T19%3A11%3A52Z&se=2026-10-28T20%3A11%3A52Z&sr=c&sp=r&sig=g5K3%2BLNxmd26a0xGEI6UABDJ7GHuSkru79zeaMjH3FA%3D)