Release Notes
Glossary
Symbols Guide
Book a Training
Request Support
Login
Beta
Ask Eddy AI
Contents
x
IMS Platform (General)
User Support
PEI
Fabric Maintenance
Civil
RCM
FCM
PLSS
TAT
SIS
Document History and Authors
Powered by
PEI Trending and Corrosion Analysis
17 Articles
in this category
Contributors
Print
Dark
Light
Contents
PEI Trending and Corrosion Analysis
17 Articles
in this category
Written by
Elsa Tolsma
Dark
Light
S-IDAP - Overview
This online manual explains how to: Process, analyze and visualize Wall Thickness (WT) data from one or more Circuits from one or more pieces of Equipment or Corrosion Loops (CLs) to: Detect Anomalies in the WT readings. Flag rea...
Written by
Elsa Tolsma
Updated on : 05 Nov 2024
S-IDAP Methodology - Dynamic Linear Modeling (4 Models explained)
S-IDAP uses Dynamic Linear Model (DLM) Corrosion Rate Calculations. Wall loss through corrosion by nature is a time dependent process. However, since the environmental and process conditions are usually varying over time, it is seldom a strictly lin...
Written by
Elsa Tolsma
Updated on : 05 Nov 2024
Data Selection and starting S-IDAP
The data (from multiple Circuits) can be selected from: Equipment Main Screen / Details Page, Circuit Main Screen / Details Page, or Corrosion Loop (CLs) Main Screen / Details Page. To select the data: Select the Equipment / Circuit(...
Written by
Elsa Tolsma
Updated on : 30 Sep 2024
S-IDAP Equipment and Circuits Overview Section
After you have selected the Circuits of interest an overview of the Equipment and Circuits is given (in View 1 (opening screen) ). Selecting the Circuits for Data Analysis The first step is to select one or more Circuits for which the data anal...
Written by
Elsa Tolsma
Updated on : 05 Nov 2024
S-IDAP Details Page Orientation
There are three views in the S-IDAP module. View 1: The opening screen The screen is divided into the following items: The Equipment and Circuits overview . Calc Summary . Approval panel . Results Tab . Measurements Tab . ...
Written by
Elsa Tolsma
Updated on : 05 Nov 2024
S-IDAP Results Tab
The Results tab is available in View 1 (opening screen) . The purpose of the Results tab is to show which CMLs/MPs have Anomalies and to provide an overview of the different Corrosion Rates for the MPs. Results Grid Information In the grid, th...
Written by
Elsa Tolsma
Updated on : 20 Sep 2024
S-IDAP Measurements Tab
The Measurements tab is available in View 1 (opening screen) . The Measurement tab shows the hierarchy, the readings and the status of the readings. In a cell, on the right side of the reading, we can have the character L, S, B, W, E, T, G, V ...
Written by
Elsa Tolsma
Updated on : 20 Sep 2024
S-IDAP Overview Plot Tab
The Overview Plot tab is available in View 1 (opening screen) . With this tab selection, the screen displays the Corrosion Rate, the Remnant Life, or the Wall Thickness of each CML and their measurement position in a bar chart. So, the number of ...
Written by
Elsa Tolsma
Updated on : 08 Oct 2024
S-IDAP Histogram Tab
The Histogram tab is available in View 1 (opening screen) . This tab displays the selected Corrosion Rate or the Remnant Life in a histogram. In the example below, higher Corrosion Rates are present in one or more Circuits. Next to the selection ...
Written by
Elsa Tolsma
Updated on : 20 Sep 2024
S-IDAP TrendPlot Tab
The TrendPlot tab is available in View 1 (opening screen) . This plot shows the data based on the S-IDAP algorithm. The example above shows the following items: The plot on the right side is from the selected row in the Results tab or or Me...
Written by
Elsa Tolsma
Updated on : 20 Sep 2024
S-IDAP Isometric Tab
The Isometric tab is available in View 1 (opening screen) . By selecting this tab, the AutoCAD isometric is displayed. Screen functionalities Colouring CMLs: You can choose to colour the CMLs using the following options from the dropdown box...
Written by
Elsa Tolsma
Updated on : 20 Sep 2024
S-IDAP TrendPlots
The Trendplots are are shown in the bottom of View 1 (opening screen) . Number of Plots The number of Trendplots displayed depends on the number of rows visible in the Results tab or Measurements tab . For example, if the number of rows is se...
Written by
Elsa Tolsma
Updated on : 20 Sep 2024
S-IDAP Readings and Edit Measurements Tabs
The Reading and Edit Measurement tab is available in View 3 (grid view) . The screen displays the trending information of the measurement position. Reading Tab The data in the TrendPlot tab is shown in the grid. Example: In the grid, the...
Written by
Elsa Tolsma
Updated on : 20 Sep 2024
S-IDAP Additional Functions and Settings
The S-IDAP Details Page header includes several additional functions. Below is an explanation of each function: Header Functions Measurement Set Configurator Clicking this button opens the configuration measurement set page in the Equipment ...
Written by
Elsa Tolsma
Updated on : 05 Nov 2024
S-IDAP Approval Panel
With this option you can Approve the selected Circuit’s Calculation Summary.
Written by
Elsa Tolsma
Updated on : 20 Sep 2024
S-IDAP References
Mike West and Jeff Harrison: “Bayesian Forecasting and Dynamic Models”, Springer ISBN 0-387-94725-6.
Written by
Elsa Tolsma
Updated on : 20 Sep 2024
Appendix: Analysis of a Dynamic Linear Model (DLM)
The formulas of the DLM are described below. Example DLM Metric In this example the following data will be used: In this example, every year a reading is taken but that’s not necessary, the algorithm works also for other time intervals. Let’...
Written by
Elsa Tolsma
Updated on : 04 Nov 2024
Change password!
Changing your password will log you out immediately. Use the new password to log back in.
Current password
Current password is required
New password
New password must be at least 8 characters long. It should contain at least one upper and lower case letter, number, and a special character.
Confirm password
Confirm password must be at least 8 characters long. It should contain at least one upper and lower case letter, number, and a special character.
Confirm password should be same as new password
Update
Change profile
Success!
First Name
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last Name
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
New email
Enter a valid email
Re-enter your password
Enter a valid password
Your profile has been successfully updated.
Update
Logout
ENTER
ESC
Eddy AI, facilitating knowledge discovery through conversational intelligence
Search Limit Exceeded. Please upgrade the plan.
Answer copied!
No results found
Provide more context or information so that I can better understand and assist you