Rich Amine Corrosion Parameters affecting severity & IOW.
| Parameter | Influence | IOW |
| --- | --- | --- |
| Material | Carbon and low alloy steels | |
| Amine Concentration (wt%) | Determine the amine concentration in the Equipment/ piping. Due to vaporization of water, a local increase in amine concentration may need to be considered in evaluating the corrosion of some reboilers and reclaimers. | Yes |
| Acid Gas Loading (mole acid gas/mole active amine) | Determine the acid gas loading in the amine. If analytical results are not available, it should be estimated by a knowledgeable process engineer. | Yes |
| Velocity (m/s; ft/s) | Determine the maximum velocity of the amine in this Equipment/piping. Note: If required for monitoring purposed, requires recalculation into (mass) flow. | |
| Heat Stable Amine Salt (HSAS) | In MEA and DEA, "HSAS" represents the normal family of amine degradation products. In MDEA "HSAS" refers to organic acid contaminants, mainly formate, oxalate, and acetate. Note: Concentration: MEA and DEA (£ 2, 2-4 or > 4wt.%); MDEA (< 500, 500-4000 or > 4000 ppmw) | Yes |
| Maximum Process Temperature (°C; °F) | Determine the maximum process temperature. In reboilers and reclaimers, tube metal temperatures may be higher than the bulk process temperature. Note: Absorber column typically below 88°C (190°F). | Yes |
Generic IOW Table for Rich Amine Corrosion Loops:
| Equipment/ Stream / Location (Tag) | Parameter | Measurement unit | Typical measurement frequency | Limit Category (and Type) |
| --- | --- | --- | --- | --- |
| Absorber bottom | Maximum acid gas loading | molacid/molamine | Typically, once a day | Standard / Monitoring (Max.) |
| Absorber bottom temperature calculated from the temperature measured just before the let-down valve. | Temperature | °C | Continuously | Standard (Max.) |
| Rich solvent | Flow rate | m/s | TBD / Site specific (e.g., depends on stability of the operation) | Monitoring (Max.) |
| Rich solvent | Flow rate | m/s | TBD / site specific | Monitoring (Min) |
| Rich amine: Lean-rich exchanger tubes and piping downstream Lean-rich exchanger | Temperature | °C | TBD / Site specific; preferably continuous | Standard / Monitoring (Max.) |
| Lean amine | Solvent strength | wt.% | Typically, once a day (depends on frequency of fluctuations of the solvent strength) | Standard / Monitoring (Max.) |
| Lean amine | Chloride content | ppmw | TBD / Site specific | Monitoring (Max.) |
| Lean Amine | pH | - | TBD / Site specific / typically 3 times a week (but much more frequent than the "fingerprint" or "Huntsman" analyses). | Standard / Monitoring (Min.) |
| Lean Amine | Maximal content of heat stable amine salts (HSAS). | wt.% on total solvent | Site specific but recommended at least once per quarter and additional when the pH IOW is on or nearing the limit. | Monitoring (Max.) |
| Lean Amine | Maximal Total Suspended Solids (TSS) | ppmw | TBD / Site specific | Monitoring (Max.) |