• Beta
Methodology Step 4
  • 09 Aug 2024
  • 1 Minute to read
  • Contributors
  • Dark
    Light
  • PDF

Methodology Step 4

  • Dark
    Light
  • PDF

Article summary

Step 4 Determine the most Credible Failure Scenario:

Below the Step 4 Methodology is described. See also Software Step 4.


The credible failure scenario should be established by the RBI team. They should consider the expected DM, process conditions, the Equipment design, operating history, and inspection history.

A complete failure scenario should describe the failure itself (left-hand side of the bowtie), the top event, and the Barriers on the right-hand side of the bowtie. In general, this would include a description of:

  • The failure location (on Equipment)
  • The hole size
  • The leak rate
  • The products leaked (their flammability [Nf factor] and toxicity [Nh factor)
  • The formation of liquid pool or gas cloud
  • Ignition sources (e.g., auto ignition, no ignition sources, road presence, etc.)
  • The location where leaked liquid will go to (e.g., oil containing sewer, surface water, soil)
  • Detection of the leak
  • Presence of people

An example of a Credible Failure Scenario is: “50 bar methane gas leak from 6 mm hole, containing < 1000 ppmw H2S at 60°C at approx. 650 kg/h forming a flammable gas cloud in semi-congested area without ignition sources. Unit down time for temporary repair 2 days.”

Specific Guidance Summary

Guidance per Special Emphasis gives additional information with regards to Special Emphasis Components (see the table below).

Specific guidance summary - Credible Failure Scenario:

DM / Special Emphasis Component
Description

Pressure Relief Devices 

For PRVs, define the Failure on Demand Scenarios.

Tanks

If planning to do Load Case calculations, then fill in the required Specs needed for the Load Case 1 calculations (see Tank Equipment).






Was this helpful? Click to add feedback comments

Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.
ESC

Eddy AI, facilitating knowledge discovery through conversational intelligence