The Results tab is available in View 1 (opening screen). The purpose of the Results tab is to show which CMLs/MPs have Anomalies and to provide an overview of the different Corrosion Rates for the MPs.
Results Grid Information
In the grid, the following columns will be displayed:
Header | Description |
---|---|
Equipment | The EquipmentID |
Circuit | The Circuit name |
Subcircuit | The sub-Circuit name |
CML | The condition measurement location |
MP | The condition measurement position |
Type | The CML type (Pipe, Elbow, …) |
Anomaly | This column contains a red cross if an anomaly has been detected in the data trend. So the S-IDAP will use either Model 2, 3 or 4. See S-IDAP Methodology - Dynamic Linear Modeling for more information on these 4 models. |
Anomaly last 2 | This column contains a red cross if an anomaly has been detected in the data trend in one of the last two readings. Thus, in the picture above, only for the last picture |
Max CR | The max CR of ShortCR, Long CR, LinRegCR, Sugg CR and S-IDAP CR (taking the S-IDAP CR into account makes it different compared to the Calc Summary, this CR is not used in the calc summary) |
Min RL | The minimum remaining life for that CML/MP |
Min NID | The minimum next inspection date for that CML/MP |
Validated | In here the user can specify that he/she has validated the data. Select the Edit button at the beginning of the row (pencil icon), (un)select Validated, add a comment and hit the Save button. |
Comment | In here the user can specify a comment for the CML/MP. See above. |
S-IDAP CR | The corrosion rate based on the dynamic linear model |
S-IDAP RL | The remaining life corresponding to the S-IDAP CR (only for display purposes) |
S-IDAP NID | The next inspection date corresponding to the S-IDAP CR |
Short CR | The short corrosion rate |
Short RL | The remaining life corresponding to the short corrosion rate |
Short NID | The next inspection date corresponding to the short corrosion rate |
Long CR | The long term corrosion rate |
Long RL | The remaining life corresponding to the long corrosion rate |
Long NID | The next inspection date corresponding to the long corrosion rate |
LinReg CR | The corrosion rate based on linear regression |
LinReg RL | The remaining life corresponding to the linear regression corrosion rate |
LinReg NID | The next inspection date corresponding to the linear regression corrosion rate |
R2 | The R-squared value. |
Sugg CR | The suggested corrosion rate for the circuit |
Sugg RL | The remaining life corresponding to the suggested corrosion rate |
Sugg NID | The next inspection date corresponding to the suggested corrosion rate |
Renewal Thickness | The renewal thickness |
RCA | The remaining Corrosion Allowance |
Toolbar
On the top of the grid the following functionalities are available:
In the order of
Search
Expand the grid to the full size of the screen
Export the grid to an Excel file
Show information about the CML/MP
The Filter feature
Settings in the grid. In here the columns can be frozen and the order of column titles can be changed.
Data Analysis Steps
The steps that always are recommended to be performed are:
Sort on the Anomalies.
Investigate the Anomalies.
Sort on max Corrosion Rate with the highest Corrosion Rate at the top of the grid.
Investigate the CMLs/MPs with these high Corrosion Rates.
Sort on minimum Remaining Life with the earliest in time at the top of the grid.
Investigate the CMLs/MPs with the shortest Remaining Life.