--- title: "FFS Number of projection lines in DNV RPF 2010 and 2015" slug: "appendix-2-number-of-projection-lines-in-dnv-rpf-2010-and-2015" updated: 2026-03-09T10:16:09Z published: 2026-03-09T11:26:58Z canonical: "ims-handbook.cenosco.com/appendix-2-number-of-projection-lines-in-dnv-rpf-2010-and-2015" --- > ## Documentation Index > Fetch the complete documentation index at: https://ims-handbook.cenosco.com/llms.txt > Use this file to discover all available pages before exploring further. # FFS Number of projection lines in DNV RPF 2010 and 2015 From release 3.13C there is a change in the calculation of the number of projection lines in the DNV method. Before 3.13C the projection lines were calculated with the formula: Int(sqrt(Diameter / Wall Thickness/Diameter)) + 1 From release 3.13C the projection lines are calculated with the formula: Int(sqrt(Diameter / Wall Thickness/Diameter)) Example, for a diameter of 10” which is 273.1mm and a wall thickness of 7 mm the number of projection lines before 3.13C was Int(sqrt(273.1/10))+ 1 = Int(6.24) + 1 = 6 + 1 = 7 From release 3.13C it is Int(sqrt(273.1/10))+ 1 = Int(6.24) = 6, more conservative ## References - 03 w-PIMS Design Data and Sectioning Theory Release 3.0, SR.16.12032 - Web based Pipeline Integrity Management Software Fitness for service assessment of SR.14.13139. - DNV RP-F101 - Corrodate Pipelines.pdf, this document is available in w-PIMS Help in folder References. The ASME’s and ISO 13623 documentation is also available in w-PIMS Help.