--- title: "Deactivating Object Types" slug: "deactivating-object-types" updated: 2026-03-09T10:15:38Z published: 2026-03-09T11:26:39Z canonical: "ims-handbook.cenosco.com/deactivating-object-types" --- > ## Documentation Index > Fetch the complete documentation index at: https://ims-handbook.cenosco.com/llms.txt > Use this file to discover all available pages before exploring further. # Deactivating Object Types (Unit / FLOC / Equipment / etc.) Take noteThere are three ways to deactivate Object Types (Unit / FLOC / Equipment / Corrosion Loop / Circuit / Component / ECH / Schedule) in IMS:  - Manually, - In bulk, - Unit Deactivation. When deactivating an Object Type in IMS, all its child objects will be deactivated as well. Consider the possibility that FLOCs that are shared with another discipline may be deactivated as part of the process. If this is the case, please consult the responsible Focal points of that discipline before continuing. This is valid for all three methods of deactivating Object types which will be explained in this article. ## Manually Deactivating Object Types This way of deactivating Object types will require you to deactivate them one by one. To manually deactivate a piece of Equipment, and its child objects (Components, Schedules, ECHs): - Navigate to the Details page of the Equipment you would like to deactivate. - In the Details section, click **Edit**. - Uncheck the Active checkbox. ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/manually-deactivate-equipment(1).png?sv=2026-02-06&spr=https&st=2026-11-22T14%3A05%3A20Z&se=2026-11-22T15%3A05%3A20Z&sr=b&sp=r&sig=SysS364TZYzyt4%2BtLRCyCbB3%2FQBYFykKnBLKOxixp7c%3D)Uncheck Active Checkbox to deactivate the Equipment. - Click **Save**. The following message will appear asking you if you also want to deactivate the FLOC. ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/floc-inactive.png?sv=2026-02-06&spr=https&st=2026-11-22T14%3A05%3A20Z&se=2026-11-22T15%3A05%3A20Z&sr=b&sp=r&sig=LTTn1l2%2BcHqTge270IL6jCHjoXjkh8RnNSIX%2B2wmRUg%3D)Select Yes or No to indicate whether you wish to deactivate or keep the FLOC active. > Example: > > In the example below, the Equipment "mra eq 8" had the active Schedule "DFLT00247553" connected to it. > > ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/Screenshot_131(1).png?sv=2026-02-06&spr=https&st=2026-11-22T14%3A05%3A20Z&se=2026-11-22T15%3A05%3A20Z&sr=b&sp=r&sig=4ZmN0SLE%2BHkmMGHab8C6QZ7NAJAhciYMwcDW5VBeJoc%3D)Active Schedule on the Equipment before deactivating the Equipment. > > After deactivating the Equipment "mra eq 8", the Schedule "DFLT00247553" got deactivated as well. > > ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/Screenshot_132.png?sv=2026-02-06&spr=https&st=2026-11-22T14%3A05%3A20Z&se=2026-11-22T15%3A05%3A20Z&sr=b&sp=r&sig=NF%2BF1tQzVy7UrvOlDDSo4yiyWN9VY9QRk91oU1WuueQ%3D)Inactive Schedule on the Equipment after deactivating the Equipment. ## Deactivating Object Types in Bulk When more than one Object type needs to be made Inactive, it can be done using the Export for Import option. In the images below, how to deactivate Objects of the type Equipment is shown. - Use the [Scope bar](https://ims-handbook.cenosco.com/v410/docs/basic-navigation-other-main-menu-options#scoping) to select one or more Units that contain the Object type you want to deactivate. - Tick the checkbox on the left of the applicable Object type. - Click the *Export* button. ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/Screenshot_134.png?sv=2026-02-06&spr=https&st=2026-11-22T14%3A05%3A20Z&se=2026-11-22T15%3A05%3A20Z&sr=b&sp=r&sig=%2BxfY4KulGheWN%2F8JNZ64dBx3DjBVVMANsPgr5Iml1Aw%3D)After selecting the Scope, select the Equipment to deactivate and click the Export button. - Click the **Export** button next. - Open the Excel file that has been downloaded. - Find the column named Active. - Use the *dropdown arrow* to change the Status of the Objects from "Active" to "Inactive". ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/Screenshot_135.png?sv=2026-02-06&spr=https&st=2026-11-22T14%3A05%3A20Z&se=2026-11-22T15%3A05%3A20Z&sr=b&sp=r&sig=JsTkPJmdMBVD8gjnU6n6c%2F4PRw0L6VxnRVZzMY6QWXA%3D)Click on the dropdown arrow in the active column to change the status of the Object from Active to Inactive. - Save the file to your computer. - Go back to IMS. - Click the *Import* button. - Make sure that the accurate import type is selected (in this case "Equipment") and click **Browse**. ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/Screenshot_136.png?sv=2026-02-06&spr=https&st=2026-11-22T14%3A05%3A20Z&se=2026-11-22T15%3A05%3A20Z&sr=b&sp=r&sig=IllNWfvO0veRwMYXkihRJrs5giJ8KFAorEERjKZvDD8%3D)Select the import type "Equipment" and click Browse. - Click **Next** a couple of times until you get to Step 5 out of 5. - Click **Show entities** to see the updated Objects. For more about importing data see [Importing Data via Settings](/v410/docs/importing-data-via-settings). ## Unit Deactivation In IMS, it is possible to deactivate a whole Unit with all its child Objects. WarningAlthough this is the quickest method, it should be avoided in cases where a large scope of Equipment is involved. To deactivate a Unit: - Click **Settings.** - Under Settings\Company\Toplevel\CMMS Hierarchy select the Site, Plant, and Unit. - Open the **Details** Tab. ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/Screenshot_137.png?sv=2026-02-06&spr=https&st=2026-11-22T14%3A05%3A20Z&se=2026-11-22T15%3A05%3A20Z&sr=b&sp=r&sig=E9B0siH62TULNEFmQ9rI37Aemnt%2FKH6VIAUGmpmQuOg%3D)Select the Unit and open the Details Tab. - Click **Edit**. - Uncheck the Active checkbox. A message will appear asking you if you want to deactivate associated FLOCs and Corrosion Loops. - Click **OK**.