--- title: "Corrosion Monitoring" slug: "corrosion-monitoring" updated: 2026-10-27T23:12:11Z published: 2026-10-27T23:12:11Z canonical: "ims-handbook.cenosco.com/corrosion-monitoring" --- > ## Documentation Index > Fetch the complete documentation index at: https://ims-handbook.cenosco.com/llms.txt > Use this file to discover all available pages before exploring further. # PL Internal Corrosion - Corrosion Monitoring ## The Long and Short Corrosion Rates from one or more Probes can be imported in PLSS via an ECH [Dynamic Form](/v414/docs/ims-dynamic-forms) and shown in the Corrosion Monitoring section. ![Graphical user interface, application Description automatically generated](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pl-2-int-corr-temp-image-6mk8l1ju.png?sv=2026-02-06&spr=https&st=2026-10-28T20%3A00%3A27Z&se=2026-10-28T21%3A00%3A27Z&sr=c&sp=r&sig=jhj16droLOB8Bhu%2FQpdf2q%2Fv9J53VntbA%2Ff8jIgS0vw%3D) To import the Long and Short Corrosion Rates: - Define the Probes in the [Inspection Locations on the Equipment Details Page](https://ims-handbook.cenosco.com/v414/docs/plss-equipment-details-page#inspection-locations) of your Equipment. The Inspection Location, Description, and Type are mandatory. The other fields are optional. In the example below two probes have been defined: ![Table Description automatically generated](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pl-2-int-corr-temp-image-s5m0xaq7.png?sv=2026-02-06&spr=https&st=2026-10-28T20%3A00%3A27Z&se=2026-10-28T21%3A00%3A27Z&sr=c&sp=r&sig=jhj16droLOB8Bhu%2FQpdf2q%2Fv9J53VntbA%2Ff8jIgS0vw%3D) Note: the Type must be set to "Probe"! - Go back to the Corrosion Monitoring section. - Click *Plus* to add the Probe data. ![Graphical user interface, application Description automatically generated](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/Screenshot_177.png?sv=2026-02-06&spr=https&st=2026-10-28T20%3A00%3A27Z&se=2026-10-28T21%3A00%3A27Z&sr=c&sp=r&sig=jhj16droLOB8Bhu%2FQpdf2q%2Fv9J53VntbA%2Ff8jIgS0vw%3D)Click on the Plus button to add the Probe data. - Enter Condition Date and Description in the Condition History pop-up window. Note: The Condition Date is the date when the probe data was recorded. - Click **Save**. ![Graphical user interface, application Description automatically generated](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pl-2-int-corr-temp-image-umn6gkys.png?sv=2026-02-06&spr=https&st=2026-10-28T20%3A00%3A27Z&se=2026-10-28T21%3A00%3A27Z&sr=c&sp=r&sig=jhj16droLOB8Bhu%2FQpdf2q%2Fv9J53VntbA%2Ff8jIgS0vw%3D) - On the ECH Details Page of the created ECH navigate to the Schedules credited section. - Click **Select**, or if there is a Probe Schedule, click the **Credit** button: ![Graphical user interface, text, application, email Description automatically generated](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pl-2-int-corr-temp-image-xf9wzsmk.png?sv=2026-02-06&spr=https&st=2026-10-28T20%3A00%3A27Z&se=2026-10-28T21%3A00%3A27Z&sr=c&sp=r&sig=jhj16droLOB8Bhu%2FQpdf2q%2Fv9J53VntbA%2Ff8jIgS0vw%3D) - In the Inspection data and codes section, click here on the *Arrow* button and select "Probe Input": ![Graphical user interface, application Description automatically generated](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pl-2-int-corr-temp-image-fta325oc.png?sv=2026-02-06&spr=https&st=2026-10-28T20%3A00%3A27Z&se=2026-10-28T21%3A00%3A27Z&sr=c&sp=r&sig=jhj16droLOB8Bhu%2FQpdf2q%2Fv9J53VntbA%2Ff8jIgS0vw%3D) This will show the Probe Dynamic Form: ![Graphical user interface, text, application, email Description automatically generated](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pl-2-int-corr-temp-image-men1bwct.png?sv=2026-02-06&spr=https&st=2026-10-28T20%3A00%3A27Z&se=2026-10-28T21%3A00%3A27Z&sr=c&sp=r&sig=jhj16droLOB8Bhu%2FQpdf2q%2Fv9J53VntbA%2Ff8jIgS0vw%3D) - Click on the first Probes Stage Card to open the Stage. ![Graphical user interface, text, application, email Description automatically generated](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pl-2-int-corr-temp-image-di703vku.png?sv=2026-02-06&spr=https&st=2026-10-28T20%3A00%3A27Z&se=2026-10-28T21%3A00%3A27Z&sr=c&sp=r&sig=jhj16droLOB8Bhu%2FQpdf2q%2Fv9J53VntbA%2Ff8jIgS0vw%3D) - Add the Probe data manually or import it from an Excel file. ![Graphical user interface, text, application Description automatically generated](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pl-2-int-corr-temp-image-aq7hs9xr.png?sv=2026-02-06&spr=https&st=2026-10-28T20%3A00%3A27Z&se=2026-10-28T21%3A00%3A27Z&sr=c&sp=r&sig=jhj16droLOB8Bhu%2FQpdf2q%2Fv9J53VntbA%2Ff8jIgS0vw%3D) - **Final Approve** the ECH. - Return to the Internal Corrosion module to see the newly entered data. ![Graphical user interface, chart Description automatically generated with medium confidence](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pl-2-int-corr-temp-image-bw5b50nj.png?sv=2026-02-06&spr=https&st=2026-10-28T20%3A00%3A27Z&se=2026-10-28T21%3A00%3A27Z&sr=c&sp=r&sig=jhj16droLOB8Bhu%2FQpdf2q%2Fv9J53VntbA%2Ff8jIgS0vw%3D)