--- title: "MiRO CMLs" slug: "miro-cmls" updated: 2026-10-27T23:12:37Z published: 2026-10-27T23:12:37Z canonical: "ims-handbook.cenosco.com/miro-cmls" --- > ## Documentation Index > Fetch the complete documentation index at: https://ims-handbook.cenosco.com/llms.txt > Use this file to discover all available pages before exploring further. # MiRO CMLs You always need to define CMLs for your Circuit. This is where the Measurements will take place, at the Measurement Points (MPs). ## Creating CMLs - Go to the Circuit Details Page. - Scroll down to the **CML** tab. - Click the *Plus* button. ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pic%201-U422YHDR.png?sv=2026-02-06&spr=https&st=2026-10-28T14%3A20%3A18Z&se=2026-10-28T15%3A20%3A18Z&sr=c&sp=r&sig=zTDwQ3qGWTMjhTk3LhtzMoQIdk1ApCcp0WL2gaAx380%3D) - Enter the required data in the pop-up window. See the table below. - Click **Save** when done. The new Circuit will be created, and you will be redirected to the Detail Page of the CML that was just created. NoteYour content goes hereYou can open a CML Details Page at any time by clicking on the hyperlink in the CML column on the **CML** tab in the Circuit Details Page. CML pop-up (pay specific attention to the field indicated in bold): | Field | Description | | --- | --- | | Circuit | The Circuit ID. This should already be selected. | | **Sub Circuit** | Sub-Group of the selected Circuit, for grouping similar CMLs within a Sub-Circuit. The Sub-Circuit-CML combination should be unique. If you do not want to group CMLs you can use this as a short description. It is a mandatory field. | | **CML** | The CML ID. This will become a hyperlink in the CML grid that you can click to open the CML Details Page. | | **CML Type** | Type of CML (e.g., PIPE, HEADER BOX, REDUCER, TEE, SHELL, CHANNEL, NOZZLE). | | CML Description | This can be used for an optional description (in addition to the Sub Circuit). | | Must Get | Check if this CML must always be measured. | | Position | Position of the CML in the Circuit. | | **MP Configuration** | For MiRO Pipes, select the "Pipe - 6 x 1" configuration. | | Active | By default the CML should be Active. | | **Piping Class** | Applicable to Pipes. Select the [Piping Class to set other parameters on the CML](/v414/docs/miro-cmls#assigning-a-piping-class-to-a-cml). | | Material | Select from predefined list. | | Nominal Diameter | Select a predefined Diameter. | | Nominal WT | Nominal Wall Thickness for the CML. | | Actual OD | Actual Outside Diameter | | **Renewal Thickness** | Minimum Wall Thickness (WT) for the selected CML. | | Renewal Basis | Renewal basis, either CALCULATED, FITNESS FOR SERVICE, NOMINAL MINUS CORR ALLOWANCE, STRUCTURAL MIN. | | Required Inspection Method | Option to set a required Inspection Method (e.g. UT, RT) for all measurement for the CML (optional). Use UT-R for datalogger import and UR for the [DIMATE-PACS interface](/v414/docs/dimate-pacs-interface). | | **Design Corrosion Allowance** | Mandatory. | | Drawing Filename | Search for and add a related drawing. | | Line number on drawing | Line number on drawing | | Line number in P&ID | Line number in P&ID | | Sketch number | Sketch number | | Longitude | Longitude | | Latitude | Latitude | | Altitude | Altitude | ## Assigning a Piping Class to a CML When a CML is created you can assign a Piping Class to it. The Piping Class sets: - Material - Available Nominal Diameters to select from Then the selected Nominal Diameter – sets: - Nominal WT - Renewal Thickness (from Over. Renewal WT as defined in the Piping Class) - Actual OD (from Diameter as defined in the Piping Class) - Design CA (Corrosion Allowance) This data comes from the Piping Classes that are [defined in Settings](/docs/miro-specific-settings#defining-piping-classes-in-settings). ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pic%201-UH2VV0XL.png?sv=2026-02-06&spr=https&st=2026-10-28T14%3A20%3A18Z&se=2026-10-28T15%3A20%3A18Z&sr=c&sp=r&sig=zTDwQ3qGWTMjhTk3LhtzMoQIdk1ApCcp0WL2gaAx380%3D) ## Calculating Minimum Wall Thickness(TMIN) The CML Details page allows you to calculate the Minimum Wall Thickness using the [TMIN Calculators](https://ims-handbook.cenosco.com/v414/docs/minimum-wall-thicknes-tmin-calculations). These calculators are based on recognized industry standards, specifically ASME Section VIII (Vessels, Heat Exchangers) and ASME B31.3 (Process Piping). See [Calculating Renewal Thickness with TMIN Calculator](https://ims-handbook.cenosco.com/v414/docs/pei-condition-measurement-locations-cmls-details-screen#calculating-renewal-thickness-with-tmin-calculator). ## The CML Tab The CML section provides a list of CMLs for the selected Circuit. The **CML** tab shows an overview of the CMLs. The CML grid columns are explained [here](/docs/miro-cmls#CML). The CML section is used to create and maintain the applicable CMLs for the selected Circuit. The grid shows a toolbar which can be used to do so. CML toolbar: | Icon | Action | Description | | --- | --- | --- | | ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pei-circuits---details-page-image-nzakqsox.png?sv=2026-02-06&spr=https&st=2026-10-28T14%3A20%3A18Z&se=2026-10-28T15%3A20%3A18Z&sr=c&sp=r&sig=zTDwQ3qGWTMjhTk3LhtzMoQIdk1ApCcp0WL2gaAx380%3D) ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pei-circuits---details-page-image-61eu5u95.png?sv=2026-02-06&spr=https&st=2026-10-28T14%3A20%3A18Z&se=2026-10-28T15%3A20%3A18Z&sr=c&sp=r&sig=zTDwQ3qGWTMjhTk3LhtzMoQIdk1ApCcp0WL2gaAx380%3D) | Edit or Cancel and Save | Edit or if in Edit mode the Cancel and Save buttons show. Save changes you made in the editable grid (such as Renewal Thickness, Renewal Basis or Nominal WT). | | ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/image-1695402631232.png?sv=2026-02-06&spr=https&st=2026-10-28T14%3A20%3A18Z&se=2026-10-28T15%3A20%3A18Z&sr=c&sp=r&sig=zTDwQ3qGWTMjhTk3LhtzMoQIdk1ApCcp0WL2gaAx380%3D) | New and Delete | Create a new CML, which opens a new screen in which CML data for the new CML should be populated. Or Delete an Existing CML. | | ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/image-1695402654920.png?sv=2026-02-06&spr=https&st=2026-10-28T14%3A20%3A18Z&se=2026-10-28T15%3A20%3A18Z&sr=c&sp=r&sig=zTDwQ3qGWTMjhTk3LhtzMoQIdk1ApCcp0WL2gaAx380%3D) | Export | Export the list of CMLs to a Microsoft Excel file. | | ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/image-1695402667145.png?sv=2026-02-06&spr=https&st=2026-10-28T14%3A20%3A18Z&se=2026-10-28T15%3A20%3A18Z&sr=c&sp=r&sig=zTDwQ3qGWTMjhTk3LhtzMoQIdk1ApCcp0WL2gaAx380%3D) | Copy | Copy a selected CML. | | ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/image-1695402684819.png?sv=2026-02-06&spr=https&st=2026-10-28T14%3A20%3A18Z&se=2026-10-28T15%3A20%3A18Z&sr=c&sp=r&sig=zTDwQ3qGWTMjhTk3LhtzMoQIdk1ApCcp0WL2gaAx380%3D) | Paste | Paste the copied CML as a new CML, measurements are not copied. | | ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pei-circuits---details-page-image-chuy1zf4.png?sv=2026-02-06&spr=https&st=2026-10-28T14%3A20%3A18Z&se=2026-10-28T15%3A20%3A18Z&sr=c&sp=r&sig=zTDwQ3qGWTMjhTk3LhtzMoQIdk1ApCcp0WL2gaAx380%3D) | Move | Move (copy) CMLs to another Circuit. This way you can also move (copy) old wall thickness measurements to a "new Equipment". A recalculation will happen at both the origin and destination Circuit. | | ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pei-circuits---details-page-image-9yq1bbjz.png?sv=2026-02-06&spr=https&st=2026-10-28T14%3A20%3A18Z&se=2026-10-28T15%3A20%3A18Z&sr=c&sp=r&sig=zTDwQ3qGWTMjhTk3LhtzMoQIdk1ApCcp0WL2gaAx380%3D) | Select New Predefined MP | Opens the registered MPs for the CML and allows you to directly add other Measurement Point(s). | | ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pei-circuits---details-page-image-q9nsiisa.png?sv=2026-02-06&spr=https&st=2026-10-28T14%3A20%3A18Z&se=2026-10-28T15%3A20%3A18Z&sr=c&sp=r&sig=zTDwQ3qGWTMjhTk3LhtzMoQIdk1ApCcp0WL2gaAx380%3D) | Show only selected | Check to show only the selected rows. | ## The CML Measurement History Tab The **CML Measurement History** tab shows the list of Wall Thickness (WT) Measurements per actual Measurement Point (MP), performed in each Measurement Set (MSET) – Measurement date. CML Measurement History grid: | Column | Description | | --- | --- | | Active | Indicator whether the CML is active or inactive. | | Sub Circuit | Sub-Group of the selected Circuit, for grouping similar CMLs within a Sub-Circuit. The Sub-Circuit-CML combination should be unique. If you do not want to group CMLs you can use this as a short description. It is a mandatory field. | | CML | CML, click to open CML details. | | Description | Short description of the CML. | | Nominal Diameter | Nominal Diameter. | | Actual OD | Actual Outside Diameter. | | NWT | Nominal Wall Thickness. | | RWT | Renewal Wall Thickness - Minimum Wall Thickness for the selected CML | | RCA | Remaining Corrosion Allowance | | RL | Remnant Life date | | NID | Next Inspection Date | | AMP | Actual Measurement Point | CML Measurement History toolbar: | Icon | Action | Description | | --- | --- | --- | | ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pei-circuits---details-page-image-nzakqsox.png?sv=2026-02-06&spr=https&st=2026-10-28T14%3A20%3A18Z&se=2026-10-28T15%3A20%3A18Z&sr=c&sp=r&sig=zTDwQ3qGWTMjhTk3LhtzMoQIdk1ApCcp0WL2gaAx380%3D) ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pei-circuits---details-page-image-61eu5u95.png?sv=2026-02-06&spr=https&st=2026-10-28T14%3A20%3A18Z&se=2026-10-28T15%3A20%3A18Z&sr=c&sp=r&sig=zTDwQ3qGWTMjhTk3LhtzMoQIdk1ApCcp0WL2gaAx380%3D) | Edit or Cancel and Save | Edit or if in Edit mode the Cancel and Save buttons show. Save changes you made in the editable grid (such as Renewal Thickness, Renewal Basis or Nominal WT). | | ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pei-circuits---details-page-image-954qrnk9.png?sv=2026-02-06&spr=https&st=2026-10-28T14%3A20%3A18Z&se=2026-10-28T15%3A20%3A18Z&sr=c&sp=r&sig=zTDwQ3qGWTMjhTk3LhtzMoQIdk1ApCcp0WL2gaAx380%3D) | New | Create a new CML, which opens a new screen in which CML data for the new CML should be populated. Or Delete an Existing CML. | | ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/image-1695402654920.png?sv=2026-02-06&spr=https&st=2026-10-28T14%3A20%3A18Z&se=2026-10-28T15%3A20%3A18Z&sr=c&sp=r&sig=zTDwQ3qGWTMjhTk3LhtzMoQIdk1ApCcp0WL2gaAx380%3D) | Export | Export the list of CMLs to a Microsoft Excel file. | | ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pei-circuits---details-page-image-chuy1zf4.png?sv=2026-02-06&spr=https&st=2026-10-28T14%3A20%3A18Z&se=2026-10-28T15%3A20%3A18Z&sr=c&sp=r&sig=zTDwQ3qGWTMjhTk3LhtzMoQIdk1ApCcp0WL2gaAx380%3D) | Move | Move (copy) CML to another Circuit. This way you can also move (copy) old wall thickness measurements to a "new Equipment". A recalculation will happen at both the origin and destination Circuit. | | ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pei-circuits---details-page-image-9yq1bbjz.png?sv=2026-02-06&spr=https&st=2026-10-28T14%3A20%3A18Z&se=2026-10-28T15%3A20%3A18Z&sr=c&sp=r&sig=zTDwQ3qGWTMjhTk3LhtzMoQIdk1ApCcp0WL2gaAx380%3D) | Select New Predefined MP | Opens the registered MPs for the CML and allows you to directly add other Measurement Point(s). | | ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pic%201(112).png?sv=2026-02-06&spr=https&st=2026-10-28T14%3A20%3A18Z&se=2026-10-28T15%3A20%3A18Z&sr=c&sp=r&sig=zTDwQ3qGWTMjhTk3LhtzMoQIdk1ApCcp0WL2gaAx380%3D) | Legend | Click to show the legend. For more information also see [MiRO Reviewing Errors and Warning (CML History tab)](/v414/docs/m-idap-errors-and-warning). | | ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pic%201(113).png?sv=2026-02-06&spr=https&st=2026-10-28T14%3A20%3A18Z&se=2026-10-28T15%3A20%3A18Z&sr=c&sp=r&sig=zTDwQ3qGWTMjhTk3LhtzMoQIdk1ApCcp0WL2gaAx380%3D) | Condense dates | When you have many CMLs, use this option to make one column per year. | You can use the filter to find specific CMLs. For example filter for CMLs with Warnings and Errors. For more information on the Measurement quality see [MiRO Reviewing Errors and Warning (CML History tab)](/v414/docs/m-idap-errors-and-warning). ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/pic%201-L7S7DZNH.png?sv=2026-02-06&spr=https&st=2026-10-28T14%3A20%3A18Z&se=2026-10-28T15%3A20%3A18Z&sr=c&sp=r&sig=zTDwQ3qGWTMjhTk3LhtzMoQIdk1ApCcp0WL2gaAx380%3D)The filter can be used to find Warnings and Errors. See the [PEI CMLs Details page](/v414/docs/pei-condition-measurement-locations-cmls-details-screen) for more information.