--- title: "Special Emphasis Configuration" slug: "special-emphasis-configuration" updated: 2026-10-27T23:11:52Z published: 2026-10-27T23:11:52Z canonical: "ims-handbook.cenosco.com/special-emphasis-configuration" --- > ## Documentation Index > Fetch the complete documentation index at: https://ims-handbook.cenosco.com/llms.txt > Use this file to discover all available pages before exploring further. # Special Emphasis Configuration The available Special Emphasis types are defined in Settings. For each type, inspection intervals are configured. Your CSA can add or change this data. ## Special Emphasis Types For each Special Emphasis Equipment, different classes can be defined. This configuration is done in [Settings \ Maintenance \ Inspection/Schedules \ Special Emphasis](/v414/docs/inspection-schedules-settings). ![](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/special-emphasis-configuration-image-94cqpjmi.png?sv=2026-02-06&spr=https&st=2026-10-28T12%3A45%3A40Z&se=2026-10-28T13%3A45%3A40Z&sr=c&sp=r&sig=wzdADeLrWdVFkGizzLwX7jlovzZtF%2BFDGkpWakv4SqQ%3D)Special Emphasis classes are defined in settings. This configuration is done per site. The table below shows the Special Emphasis types typically available. The full list of available (and non-expired) Special Emphasis types can be found in the Settings (see the figure above). Special Emphasis types: | Category | Special Emphasis | | --- | --- | | Injection Points | IP: CLASS. A (12 MO. MAX) | | IP: CLASS. B (36 MO. MAX) | | IP: CLASS. C (36 MO. MAX) | | IP: CLASS. D (72 MO. MAX) | | IP: CLASS. E (120 MO. MAX) | | IP: CLASS. E (96 MO. MAX) | | IP: CLASS. F (NO MAX) | | Corrosive Deadleg | DL: CLASS. A (12 MO. MAX) | | DL: CLASS. B (24 MO. MAX) | | DL: CLASS. C (36 MO. MAX) | | Unstable Deadleg | Unstable: CLASS. A (12 MO. MAX) | | Unstable: CLASS. B (36 MO. MAX) | | Unstable: CLASS. C (36 MO. MAX) | | Soil to Air | SOIL TO AIR | ## Configuration of Max interval and Default interval For each Special Emphasis Type, a Default interval, as well as a Max interval, is configured in [Settings \ Maintenance \ Configuration \ Configuration per Hierarchy Type](/v414/docs/hierarchy-type-configuration-in-setting). A Special Emphasis is configured per: - FLOC Type, - Equipment Type, and - Schedule Type. For each of the above combinations a Default interval, as well as a Max interval, is set. This will impact the interval on the Corrosion / Inspection Schedule. The below figure gives an example of an Injection Point (IP) configuration for a PIPE-FLOCs. ![Graphical user interface, table Description automatically generated](https://cdn.document360.io/e492a0e0-a4ba-4aca-8fc6-76b95f91fdf3/Images/Documentation/special-emphasis-configuration-image-xv1imnyj.png?sv=2026-02-06&spr=https&st=2026-10-28T12%3A45%3A40Z&se=2026-10-28T13%3A45%3A40Z&sr=c&sp=r&sig=wzdADeLrWdVFkGizzLwX7jlovzZtF%2BFDGkpWakv4SqQ%3D)Special Emphasis (IP) configuration for PIPE-FLOCs.