When all is verified (Achieved PFD checked, Performance checked, and Response Time checked) then you can Approve your design in the Approval area.
Approval Prerequisites
The following Approval rules apply:
Unrated SIFs
Approval is allowed when Assessment Status is OK.
SIL A rated SIFs
If there is no Subsystem, Approval is allowed. Design Status (DS) show “A”. (Greenfield project)
If design is completed (Design Status (DS) shows green), Approval is allowed. (Brownfield project)
SIL ≥ 1 rated SIFs
If design is completed (Design Status (DS) shows green), Approval is allowed.
Approving the SIF Analysis
When all is good, you can Approve the SIF Analysis.
Click the Approve button to open the Approval Pane.
Review any Warning shown.
Select the Approval Level (if applicable).
Click Approve.
.png?sv=2022-11-02&spr=https&st=2025-06-15T23%3A33%3A45Z&se=2025-06-15T23%3A45%3A45Z&sr=c&sp=r&sig=AiJSciwM2Yh2yPwly7bD6JzGzSGMr%2B3Qrrf0RF0Q4kE%3D)
Click Approve to Approve your design.
When you Approve the design the Review Status (RS) will update. This is shown on the Analysis Main Screen, as well as on the General Tab.
Creating a new Version
When already Approved, you can create a new Draft version. To do so click Edit Final Approved Analysis.
.png?sv=2022-11-02&spr=https&st=2025-06-15T23%3A33%3A45Z&se=2025-06-15T23%3A45%3A45Z&sr=c&sp=r&sig=AiJSciwM2Yh2yPwly7bD6JzGzSGMr%2B3Qrrf0RF0Q4kE%3D)
To create a new Draft version, click Edit Final Approved Analysis.
Remember you can find all versions in the Revision History tab.
Roll Back
It is possible to “roll back” to your last Approved version of the SIF Analysis. When you click Roll Back, all changes made after the Approval will be discarded.
.png?sv=2022-11-02&spr=https&st=2025-06-15T23%3A33%3A45Z&se=2025-06-15T23%3A45%3A45Z&sr=c&sp=r&sig=AiJSciwM2Yh2yPwly7bD6JzGzSGMr%2B3Qrrf0RF0Q4kE%3D)
Click Roll back to discard all changes made after Approval.
Roll Back blockers
Roll back is restricted when certain actions have been performed that impact the SIF Analysis and return it to Draft status, as outlined in the below table.
Connected Object | From where | What action |
---|---|---|
Equipment-Actor | Equipment Details Page | Changing the Equipment Name |
Changing Dangerous Failure Rate Lower or Upper range | ||
Adding or deleting a Test from the Schedule Test section | ||
Making any change to the FMEA table in the FMEA section | ||
Changing the Fault Tolerance Modifiers in the Implementation section | ||
Changing the Inherent Fault Tolerance parameter in the Implementation section | ||
Changing the Inherent ETT parameter in the Implementation section | ||
Changing the Inherent Actor in the Implementation section | ||
Changing the Mean Time To Restore setting in the Repair section | ||
Changing the On Stream Repair Possible setting in the Repair section | ||
Changing the Response Time setting in the Repair section | ||
Changing the Accuracy setting in the Repair section | ||
Function Group | Settings (changed directly by users with admin rights) | Changing the Function Group from the Function Group settings |
Subsystem | Settings (changed directly by users with admin rights or updated through a changed and then final approved SIF Analysis) | Changing the Subsystem from the Subsystem settings |
LOPA | LOPA Details Page | Not having connected LOPA in Final Approved state |
Adding new connected LOPA to DRAFT SIF | ||
Deleting connected LOPA from DRAFT SIF (Note: Rollback can only be enabled when LOPAs connected to the DRAFT SIF version are the same as LOPAs connected to the LAST FINAL APPROVED SIF version, no LOPA connected to the SIF should have been added, deleted, or sent to draft) |