The CML measurements to be used for the Corrosion Rates (CR) calculation are shown on the  CML Measurement History tab of the Circuit . The readings are classified as long, short or baseline readings. When calculating Corrosion Rates (CR) fo...
  • Updated on Jun 27, 2025
  • Published on Jan 30, 2025
The CML measurements to be used for the Corrosion Rates (CR) calculation are shown on the  CML Measurement History tab of the Circuit . IMS will identify "bad" readings (anomalies). For example, IMS will always identify when the current thick...
  • Published on Jan 30, 2025
Calculated Corrosion Rates (CRs) are displayed on the Corr Rates IF tab of the Calculation Summary . The following CRs are calculated in IMS: On CML level: Long CR, using the first and last thickness readings. Short CR, using the previous an...