Data Quantification RBI Analysis (Component) Criteria

  • Dark
    Light
  • PDF

Article summary

This article explains in detail the RBI Analysis criteria (referring to RBI Components) for the Data Quantification Section on the RBI Dashboard. To learn about the other criteria see RBI Dashboard Data Quantification.

Baseline

Baseline Components must adhere to the following criteria:

  • The Component type may not be GENERAL

  • Both the Component and Equipment must be Active

  • Equipment Status must be In Service or In Construction

  • Equipment Perform RBI must be checked

RBI components with only scenarios or no assessment

Stage I Components must meet Baseline criteria.

RBI components with scenarios and consequence assessments

Stage II Components must adhere to the following criteria:

  • Components must meet Stage I criteria

  • Components must have at least one unexpired analysis and at least one of the following two criteria must be met:

    1. Analysis performed for the NON-CORROSIVE Degradation mechanism

    2. or the Scenario must be filled in and at least one of the consequences assessments must be performed

RBI components with Stage 2 and with StF assessments

Stage III Components must adhere to the following criteria:

  • Components must meet Stage II criteria

  • At least one of the following two criteria must be met:

    1. Analysis performed for the NON-CORROSIVE Degradation mechanism

    2. or StF assessment has to be performed

RBI components with Stage 3 and with confidence assessments (corrosive injection and mix points, corrosive deadlegs counted as complete)

Stage IV Components must adhere to the following criteria:

  • Components must meet Stage III criteria

  • At least one of the following two criteria must be met:

    1. Analysis performed for the NON-CORROSIVE or any of the strategy-based Degradation mechanisms

    2. or the Confidence assessment has been performed

    3. or Component type is set to any of the following: CORROSIVE INJECTION POINT, CORROSIVE MIXING POINT, CORROSIVE DEADLEG

RBI components with Stage 4 and with Next Inspection Dates with final approved schedule or corrosion circuit

Stage V Components must adhere to the following criteria:

  • Components must meet Stage IV criteria

  • At least one of the following two sets of criteria must be met:

    1. Components are in Schedule scope

      • The Component must be in the scope of a final approved, uncredited Schedule

      • Analysis must have either RBI NID calculated or an Inspection Strategy

      • Analysis status must be Analysis completed, implemented

    1. Component inherited on a Circuit

      • Components must be inherited on a Circuit with a final approved Calc Summary

      • Analysis status must be Analysis completed, implemented


Was this helpful? Click to add feedback comments

Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.
ESC

Eddy AI, facilitating knowledge discovery through conversational intelligence