  • Dark
    Light
  • PDF

Article summary

Under specific conditions, IMS  can recommend minimum Renewal Thickness. Suggestions are provided to the Inspector so that in these specific conditions an optimal Renewal Thickness may be selected. It is left to the inspector to determine whether they should be applied.

The Renewal Thickness is recommended by DEP Min WT  configuration according to:

  • The Equipment Group has to be either Pipe or Piping System

  • CML Type has to be Elbow

  • CML Diameter has to be set to a non-zero value

  • CML Renewal Basis has to be Structural MIN

  • CML spec Base Matl has to be set to any value among the following: SS 316L, Carbon Steel, 1.25Cr-0.5Mo

  • CML spec General/Design Pressure/Actual has to be set

  • CML spec General/Design Temperature/Actual has to be set