PEI - Recommended Renewal Thickness
Under specific conditions, IMS can recommend minimum Renewal Thickness. Suggestions are provided to the Inspector so that in these specific conditions an optimal Renewal Thickness may be selected. It is left to the inspector to determine whether they should be applied.
The Renewal Thickness is recommended by DEP Min WT configuration according to:
The Equipment Group has to be either Pipe or Piping System
CML Type has to be Elbow
CML Diameter has to be set to a non-zero value
CML Renewal Basis has to be Structural MIN
CML spec Base Matl has to be set to any value among the following: SS 316L, Carbon Steel, 1.25Cr-0.5Mo
CML spec General/Design Pressure/Actual has to be set
CML spec General/Design Temperature/Actual has to be set