PLSS Release 2022.4

Prev Next

December 2022

Release 2022.4


Exporting & Importing Spare Specs

IMSFB-33765

PLSS Spares can now be exported for import from the Spare Parts Main Screen:

The exported Excel file can then be updated and imported as Hierarchy specs:

A Spare Specs filter was also added to the Spare Parts Main Screen:

Sea Water Corrosion DM split to IC & EC

IMSFB-28032

The "Sea water corrosion" DM was renamed to "Sea water corrosion (int)" and a new DM "Sea water corrosion (ext)" was added. Existing data from "Sea water corrosion (int)" was migrated to "Sea water corrosion (ext)" where applicable.

New PIMS Inspector Role

IMSFB-32324

A new PIMS Inspector role was added to PLSS. Users with this role can credit Schedules and create new ECHs to capture data in dynamic forms. They can also final approve Schedule, and edit Schedule’s and ECH’s. These user cannot add Flocs and Equipment.

Spec data added for Pipeline, Pipeline Jumper & Flowline Equipment

IMSFB-33159

For the SUKEP site, missing spec data were are added for the Pipeline, Pipeline Jumper and Flowline Equipment Groups.

The Specs are: PIPE ARRANGEMENT, NORMAL OPERATING TEMPERATURE, EXT. COATING THICKNESS, EXT. WEIGHT COATING MATERIAL, EXT. WEIGHT COATING THICKNESS, NORMAL OPERATING PRESSURE, HYDROTEST PRESSURE, HYDROTEST PRESSURE DATE, EASTING(Start/End), NORTHING(Start/End).

For the spec "Pipe Seam Type" we added the option: "Submerged arc weld  (SAW)". 

For the spec "PIPE ARRANGEMENT" we add the options: "Single pipe", "pipe-in-pipe", "bundle", "piggy-back", and "other". 

FFS Improvements

Defect  IDs added to Planned Repairs after MAOP change

IMSFB-32845

After editing MAOP details, the Defect ID's are now shown in the Planned Repairs list.

FFS - Defects Ranking graph improvements

IMSFB-32613

The title for Defects Ranking was changed from “Ranking” to “Ranking by depth”. Information about the X value, Y value and Defect ID was added in the tooltip on the graph.

FFS – Assessment Table – MAT (Minimum Allowable Thickness) and CT (Corrosion Tolerance) columns added

IMSFB-33841

The columns MAT Override, MAT, CT Override, CT (msrd), MAT (msrd), and CT Override (msrd) have been added to the Assessment Table. 

For the sites, that have MAT override specified in the Settings, CT Override and CT Override (msrd) will be calculated as well. 

 Example of MAT Override in the Settings:

MAT Calculation

  • If there is a Defect in the section (so, we have a Corrosion Tolerance for a defect):

MAT = IP Nominal WT – Defect depth – Corrosion Tolerance 

  • If there are no Defects then:

MAT = Design Nominal WT – Corrosion Tolerance (from limstate calc) 

If the MAT Override has not been specified then the remaining life calculation in the RBA module, will use the minimum CT (per section). 

If the MAT override has been specified then the remaining life calculation in the RBA module, will use the minimum CT Override (per section). 

RBA module – updates

IMSFB-33586

The fields Start Distance and Length were added.

The descriptions for the Consequence categories were updated.