S-IDAP Equipment and Circuits Overview Section

  • Dark
    Light
  • PDF

Article summary

After you have selected the Circuits of interest an overview of the Equipment and Circuits is given (in View 1 (opening screen)).

Selecting the Circuits for Data Analysis

The first step is to select one or more Circuits for which the data analyses is going to be performed. There are two ways to make this selection:

Selecting a Single Circuit

To display the data for a Single Circuit:

  • Click on the Normal Analysis button.

Table  Description automatically generated

Click the normal analysis button.

  • Select a desired Circuit.

View 1, the opening screen, will be displayed. The Circuit’s Calc Summary will show. (This will already be open if you were directed from the Measurement Set (MSET) view.)

Selecting Multiple Circuits for Bulk Analysis

To go to the Bulk analysis mode,

  • Click the Bulk analysis button.

Graphical user interface, text  Description automatically generated

Click the Bulk analysis button to go to the Bulk analysis mode.

  • Select one or more pieces of Equipment and/or one or more Circuits, by checking the box next to them.

  • Click the red Apply button to display the data in the bottom windows.

Click Apply.

Circuit / Equipment Overview Grid Information

In the grid, the following columns are displayed:

Header

Description

Checkbox + Equipment / Circuit

Tick the checkbox of the Equipment and/or Circuits of interest.

Anomaly2

If marked then an Anomaly has been detected in one of the last two readings (see S-IDAP Trendplots).

Max CR

The maximum calculated corrosion rate (ShortCR, LongCR, linear regression, suggested rate, DLM, ….) for the Circuit.

Min RL

The minimum Remnant Life for the circuit.

NID

The Next Inspection Date for the Circuit.

Short RL to IDAP NID

The data in these columns are all copied from the Calc Summary.

IDAP Status

After the analysis you can select one of the options:

The selected option is shown in this column. See Setting IDAP Status.

IDAP Status Comment

The IDAP user comment is showed in this column.

Inspection Event

The inspection event comment, e.g., Inspection Completed 8-Dec-2014.

Approval

The Approval Status, e.g., Writer Approved

Setting IDAP Status

To set the IDAP status:

  • Select the relevant Circuits.

  • Select the Status with the dropdown in the top.

Select the IDAP Status.

  • Click the Status Apply button.

Click the Status Apply button to change the Status.

This Status will be shown in the Equipment and Circuit grid and can be filtered on.

Showing Calc Summary and Approval pane

To show the Calc Summary and Approval pane click the Normal analysis button and select the desires Circuit.

Table  Description automatically generated


Was this helpful? Click to add feedback comments

Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.
ESC

Eddy AI, facilitating knowledge discovery through conversational intelligence