Heat Exchanger Bundles (Shell and Tube)

Take Note
There are some specific cases where the S-RBI assessment approach in IMS PEI changes, depending on the Equipment/Component type.
This section gives guidance for Heat Exchanger Bundles (Shell and Tube).

Define Asset – Step 1 

See Step 1.

Typically, the Heat Exchanger (HX) Channel and Shell Components will be monitored by different Circuits.

IF – Step 11 

See Step 11.

The Interval Factor is generated from the “full life” table.

Barrier Verification – Step 12 & Step 13 

See Step 12 and Step 13.

EVA is a statistical methodology that can be used to calculate and predict the corrosion for HX (Heat Exchanger) bundles.