S-IDAP Readings and Edit Measurements Tabs
The Reading and Edit Measurement tab is available in View 3 (grid view). The screen displays the trending information of the measurement position.
Reading Tab
The data in the TrendPlot tab is shown in the grid.
Example:
In the grid, the following columns are displayed:
Header | Description |
---|---|
Date | The inspection date |
WT reading | The corresponding wall thickness reading |
Quality | The quality indicator |
Insp Method | The inspection method, in example above all are UT |
Temp | The temperature |
PredWT | The predicted Wall Thickness |
PredWT Err | The error related to this prediction |
Est CR | The estimated Corrosion Rate |
Est CR err | Not filled in yet |
Post WT | The updated Wall Thickness after a reading has been taken |
P_model | The posterior probability of Model 1 |
P_outlier | The posterior probability of Model 2, the outlier model |
P_level | The posterior probability of Model 3, the change in level model |
P_change | The posterior probability of Model 4, the change in Corrosion Rate model |
Edit Measurements Tab
This tab displays a Quality Indicator for the readings of the measurement position.