• Beta
S-IDAP Readings and Edit Measurements Tabs
  • 20 Sep 2024
  • 1 Minute to read
  • Contributors
  • Dark
    Light
  • PDF

S-IDAP Readings and Edit Measurements Tabs

  • Dark
    Light
  • PDF

Article summary

The Reading and Edit Measurement tab is available in View 3 (grid view). The screen displays the trending information of the measurement position.

Reading Tab

The data in the TrendPlot tab is shown in the grid.

Example:

In the grid, the following columns are displayed:

Header

Description

Date

The inspection date

WT reading

The corresponding wall thickness reading

Quality

The quality indicator

Insp Method

The inspection method, in example above all are UT

Temp

The temperature

PredWT

The predicted Wall Thickness

PredWT Err

The error related to this prediction

Est CR

The estimated Corrosion Rate

Est CR err

Not filled in yet

Post WT

The updated Wall Thickness after a reading has been taken

P_model

The posterior probability of Model 1

P_outlier

The posterior probability of Model 2, the outlier model

P_level

The posterior probability of Model 3, the change in level model

P_change

The posterior probability of Model 4, the change in Corrosion Rate model

Edit Measurements Tab

This tab displays a Quality Indicator for the readings of the measurement position.


Was this helpful? Click to add feedback comments

Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.
ESC

Eddy AI, facilitating knowledge discovery through conversational intelligence